To get all available parameters of the device send command {"cmd":1}, for example answer for AX thermostat with firmware version 2.3:

{
   "sn":"058016000543464839373520000159",
   "par":[[0,6,"536112000"],[1,6,"536112000"],
          [2,2,"1"],[3,2,"0"],[4,1,"30"],
          [5,1,"30"],[6,1,"25"],[7,1,"5"],
          [18,2,"2"],[19,2,"10"],[21,1,"0"],
          [23,2,"6"],[25,2,"15"],[26,1,"45"],
          [27,1,"5"],[28,2,"16"],[29,1,"0"],
          [17,4,"175"],[114,7,"1"],[115,7,"0"],
          [116,7,"0"],[117,7,"0"],[118,7,"0"],
          [121,7,"0"],[122,7,"0"],[124,7,"0"],
          [125,7,"0"]]
}

sn - device serial number

par - parameter exchange key

Transfer format is an array of arrays. The first value is number of the parameter, the second its type, the third is string with the parameter value.

For example, turn on the device and set floor temperature in manual mode to 27 °C (device menu item bLc = 0FF, blocking is disabled):

{
  "sn":"058016000543464839373520000159",
  "par":[[125,7,"0"],[5,1,"27"]]
}

Answer:

In firmware version 2.5, in response, we receive an updated list of parameters:

{
 "sn":"058016000543464839373520000159",
 "par":[[0,6,"536112000"],[1,6,"536112000"],[2,2,"1"],[3,2,"0"],[4,1,"30"],
       [5,1,"27"],[6,1,"25"],[7,1,"5"],[18,2,"2"],[19,2,"10"],[21,1,"0"],
       [23,2,"6"],[25,2,"15"],[26,1,"45"],[27,1,"5"],[28,2,"16"],[29,1,"0"],
       [17,4,"175"],[114,7,"0"],[115,7,"0"],[116,7,"0"],[117,7,"0"],[118,7,"0"],
       [121,7,"0"],[122,7,"0"],[124,7,"0"],[125,7,"0"]]
}

Важно

When changing device parameters, the command must contain the key sn

Data types

Num

Type

0

CStringType

1

int8

2

uint8

3

int16

4

uint16

5

int32

6

uint32

7

bool

Parameters list

Num

Type

Name

Description

0

6 (uint32)

startAwayTime

in seconds from 01.01.2000, away start time

1

6 (uint32)

endAwayTime

in seconds from 01.01.2000, away end time

2

2 (uint8)

mode

mode: schedule=0, manual=1

3

2 (uint8)

controlType

control tupe: by floor=0, by air=1, extended=2

4

1 (int8)

manualAir

in °C, manual mode temperature by air

5

1 (int8)

manualFloorTemperature

in °C, manual mode temperature by floor

6

1 (int8)

awayAirTemperature

in °C, temperature mode away by air

7

1 (int8)

awayFloorTemperature

in °C, temperature mode away by floor

14

2 (uint8)

minTempAdvancedMode

in °C, minimum floor temperature in extended mode

15

2 (uint8)

maxTempAdvancedMode

in °C, maximum floor temperature in extended mode

17

4 (uint16)

power

in a.e., P=(power<=150)?(power*10):(1500+power*20), connected power

18

2 (uint8)

sensorType

type of connected temperature sensor: 4,7kOhm=0, 6,8kOhm=1, 10kOhm=2, 12kOhm=3, 15kOhm=4, 33kOhm=5, 47kOhm=6

19

2 (uint8)

histeresis

in 1/10 °C, hysteresis

20

1 (int8)

airCorrection

in 1/10 °C, air temperature sensor correction

21

1 (int8)

floorCorrection

in 1/10 °C, floor temperature sensor correction

23

2 (uint8)

brightness

in a.e. (from 0 to 9) brightness

25

2 (uint8)

propKoef

in minutes when load on within 30-minutes cycle of the proportional mode

26

1 (int8)

upperLimit

in °C, max setting value of the floor temperature

27

1 (int8)

lowerLimit

in °C, min setting value of the floor temperature

28

2 (uint8)

maxSchedulePeriod

max number of perioods per day

29

2 (uint8)

tempTemperature

in °C, temporary mode temperature

31

2 (uint8)

setTemperature

in °C, setting temperature of current mode (awayFloorTemperature | manualFloorTemperature | tempTemperature)

33

1 (int8)

upperAirLimit

in °C, max setting value of the air temperature

34

1 (int8)

lowerAirLimit

in °C, min setting value of the air temperature

52

4 (uint16)

nightBrightStart

in minutes from 00:00, night low bright start time

53

4 (uint16)

nightBrightEnd

in minutes from 00:00, night low bright end time

109

7 (bool)

offButtonLock

disable automatic lock of touch buttons (Read-only)

114

7 (bool)

androidBlock

local newort control block

115

7 (bool)

cloudBlock

cloud control block

117

7 (bool)

NCContactControl

inverted relay

118

7 (bool)

coolingControlWay

heat/cool mode

120

7 (bool)

useNightBright

activate using night bright

121

7 (bool)

preControl

preheat

122

7 (bool)

windowOpenControl

open window control

124

7 (bool)

childrenLock

children protect

125

7 (bool)

powerOff

power off